Door Control Switch: Inspection
- INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY
- with Power Window:
Measure the resistance according to the value(s) in the table below.
Standard resistance
TERMINAL SPECIFIED CONDITION CHARTTerminal No. Switch Position Specified Condition 1 - 3 - 5 Lock Below 1 Ω - OFF 10 kΩ or higher 1 - 3 - 8 Unlock Below 1Ω If the result is not as specified, replace the switch.
- without Power Window:
Measure the resistance according to the value(s) in the table below.
Standard resistance
TERMINAL SPECIFIED CONDITION CHARTTerminal No. Switch Position Specified Condition 3 - 6 Lock Below 1 Ω - OFF 10 kΩ or higher 3 - 5 Unlock Below 1 Ω If the result is not as specified, replace the switch.
- with Power Window:
- INSPECT DOOR CONTROL SWITCH ASSEMBLY
- Passenger's side switch:
Measure the resistance according to the value(s) in the table below.
Standard resistance
TERMINAL SPECIFIED CONDITION CHARTTerminal No. Switch Position Specified Condition 3 - 6 Lock Below 1 Ω - OFF 10 kΩ or higher 3 - 5 Unlock Below 1 Ω If the result is not as specified, replace the switch.
- Passenger's side switch: