lemon-mirror:
Home >> Triumph >> 1976 >> Spitfire >> Repair and Diagnosis >> Electrical >> Starter >> Starter Controls - LUCAS >> Testing >> Pull-In Winding

Pull-In Winding

Connect ohmmeter between small unmarked terminal of solenoid and "STA" terminal. If resistance is not within specifications, closing (series) winding are bad, replace solenoid.

Vehicle Application Resistance (Ohms)
MGB 13-.15
TR6 & TR7 25-.27
Jaguar V12 36-.42