Connect ohmmeter between small unmarked terminal of solenoid and "STA" terminal. If resistance is not within specifications, closing (series) winding are bad, replace solenoid.

Vehicle Application Resistance (Ohms)
MGB .25.27
TR7, Spitfire .25-.27
Jaguar V12 .36-.42