Airflow Sensor Potentiometer
- Turn ignition switch to "OFF" position. Remove high voltage wire from distributor ignition coil and connect to ground. Disconnect Digifant II control unit connector.
- Connect ohmmeter leads between terminals No. 6 and 17 of control until connector. Resistance should be within 500-1000 ohms. If not okay, check sensor wiring harness.
- Connect ohmmeter leads between terminals No. 17 and 21 of control unit connector. Move airflow sensor pressure flap or actuate starter. Resistance should change. If not okay, replace potentiometer.