Main Fuel Pump Volume Check
NOTE:
Before testing main fuel pump, check transfer pump. See TRANSFER PUMP CHECK .
- Remove fuel pump relay from relay panel. Activate fuel pumps using Remote Control (VAG 1348/3A). Measure voltage being applied to fuel pump when activating with remote control. Record voltage.
- Fuel volume is relative to voltage applied to fuel pumps. Activate fuel pumps for 30 seconds. Compare volume with values in FUEL PUMP PERFORMANCE table.
FUEL PUMP PERFORMANCE (1)
| Application | Pressure psi (kg/cm2 ) | Min. Vol. In 30 Sec. Pts. (L) | ||
|---|---|---|---|---|
| Passat | 58 (4.0) | 1.0-1.4 (0.5-0.7) | ||
|
||||