Using an Ohmmeter

  1. Turn ignition off. Connect negative lead of an ohmmeter to ground. Connect the other lead to terminals 11 and 25 in turn. Ohmmeter should indicate 0 ohms at both points.
  2. If any terminal shows a high resistance or infinite resistance, the wire connected to that terminal must be traced and repaired. Wires are grounded at intake manifold.