Usage Of Reload Software (TJ23502)
Publication date: 2010-09-14Reference number: TJ23502
USAGE OF RELOAD SOFTWARE
TECHNICAL SERVICE BULLETIN
| VOLVO: | 1999-2011 S80; 2001-2009 S60; 2001-2010 V70; 2003-2011 XC70, XC90; 2004-2011 S40, 2005-2011 V50; 2006-2011 C70; 2007-2011 S80; 2008-2010 V70; 2008-2011 C30, XC70; 2010-2011 XC60; 2011 S60 |
| GROUP: | 2800 |
| DESCRIPTION: | Ignition and Control System |
| REFERENCE: | VIDA |
| RELATED REF. NUMBER(S) : | US23502.1.0 en-GB |
VEHICLE TYPE
| Type | Eng | Eng Desc | Sales | Body | Gear | Steer | Model Year | Plant | Chassis range | Struc Week Range |
|---|---|---|---|---|---|---|---|---|---|---|
| 124 | 2007-9999 | 0000001-0999999 | 200605-999952 | |||||||
| 134 | 2011-9999 | 0000001-0999999 | 201020-999952 | |||||||
| 135 | 2008-2010 | 0000001-0999999 | 200720-201019 | |||||||
| 136 | 2008-9999 | 0000001-0999999 | 200720-999952 | |||||||
| 156 | 2010-9999 | 0000001-0999999 | 200905-999952 | |||||||
| 184 | 1999-9999 | 0000001-0999999 | 199815-999952 | |||||||
| 275 | 2003-9999 | 0000001-0999999 | 200232-999952 | |||||||
| 285 | 2001-9999 | 0000001-0999999 | 200020-999952 | |||||||
| 295 | 2001-9999 | 0000001-0999999 | 200020-999952 | |||||||
| 384 | 2001-9999 | 0000001-0999999 | 200031-999952 | |||||||
| 533 | 2007-9999 | 0000001-0999999 | 200637-999952 | |||||||
| 542 | 2006-9999 | 0000001-0999999 | 200549-999952 | |||||||
| 544 | 2004-9999 | 0000001-0999999 | 200339-999952 | |||||||
| 545 | 2005-9999 | 0000001-0999999 | 200420-999952 |
CSC
| Code | Description |
|---|---|
| 3L | Repair information/Repair information/Not for warranty use |
| 2V | Software/Vehicle communication/Software/Vehicle communication/Not for warranty use |
DTC
Text
CSC = Customer Symptom Code
DTC = Diagnostic Trouble Code
DESCRIPTION
This Technical Journal describes the usage of RELOAD software (SW). There are two main types of downloads; RELOAD and UPGRADE. By description, a RELOAD shall be used when a node has been replaced and an UPGRADE shall be used when new SW version shall be downloaded to an existing node.
In the SW System Structure, there is a blockage which stops you from purchasing an UPGRADE to a node, if the node already contains the latest SW. In this case VIDA will show "error 133 - the node to be upgraded already contains the latest SW".
If the node already contains the latest SW, there is absolutely no reason to perform a RELOAD to that node. This will only bring down the same SW as the node already contains, and will make no difference for the customer concern.
A lot of warranty cost is spent on these unnecessary RELOADs and they do not offer anything to the customer's concern(s).
The warranty department will start looking into these unnecessary RELOADs, both to reduce the cost and also to ensure that the correct remedy is performed in order to solve the customer's concern(s).
SERVICE
Do not use RELOAD SW to solve a SW problem if the node already contain the latest SW (error 133 when trying to perform UPGRADE, as described above), as this will not add any extra value.
There are occasions when a reload is necessary, even if the node contain the latest SW. For example, if a node does not respond at downloading, it is sometimes necessary to perform a RELOAD SW, even if the node is not replaced. Also, on recommendation from Technical Support, a RELOAD is sometimes applicable to use.