lemon-mirror:
Home >> Mazda >> 1983 >> RX-7 GSL, Automatic >> Repair and Diagnosis >> Engine Performance >> System >> Air Injection System >> Component Testing >> Switching Solenoid Valve

Switching Solenoid Valve

  1. Disconnect vacuum sensing tubes from switching solenoid valve and vacuum pipe. Blow through switching valve from vacuum sensing tube "B" in Figure . Air should pass through valve and escape from front port.
  2. Disconnect electrical connector from switching valve and connect battery power to terminals on valve.